Signal generator, spectrum analyser, power meter…

            

Attenuators, Loads, cables, dedicated to EMC

The injection probes are used in compliance tests according to the standards:

  • DO-160
  • IEC 61000-4-6
  • MIL-STD 461
  • ISO11452-4

and other susceptibility recommendations

Current probes can be used when RF current measurements are required. Current measurements are performed by placing a current-carrying conductor in the probe detection window and measuring the probe output voltage using an RF detector. Probe calibration converts measured voltages to current. Current measurements can be made over the frequency range indicated in the transfer impedance curve supplied with each probe.

  • CISPR 22/32
  • CISPR 25
  • DO-160 C,D,E,F
  • IEC 61000-4-6
  • MIL-STD 461 C,D,E,F
  • J-1113-2
  • J-1113-4 ISO11452-4
  • 1752-2

Dedicated calibration fixture:

These test devices allow the user to quickly and easily calibrate the clamp or probe before performing the compliance tests.

CDN :

The common mode current disturbance signal can be brought to the test object using various Cdns to inject the signal on uncontrolled cables, shielded cables, balanced cables, coaxial cables and mains power. Decoupling networks are used to ensure that the disturbance signal does not affect the auxiliary equipment and is placed between the test object and the auxiliary equipment.

  • CISPR 15
  • CISPR 20
  • IEC 61000-4-5
  • IEC 61000-4-6
  • IEC 61000-4-16
  • EN55015 et EN55035
  •                               
  • Full range for many cables EST (AF, M, S et T)

A line impedance stabilization network (LISN) is a device used in the emission and susceptibility testing of conducted and radiated radiofrequencies, as specified in various electromagnetic compatibility (EMC) standards/Emifilter typically passes between a AC or DC power source and the EUT to create a known impedance and provide a radio frequency noise measurement port. It also isolates unwanted RF signals from the power source

  • FCC Part 15
  • ANSI C63.4
  • CISPR 22/32
  • CISPR 25
  •   

Our range of noise sources and comb generators  is used to check the settings of the tests and measurements and ensure the validity of the test results.

. Noise sources,
. Comb generators,
. Combination: Noise source and comb generator

Shielded cameras for EMC environment: video camera via optical transmission.
for indoor or outdoor applications
Manual or automatic control as required,
Models for small rooms available
Wide range of accessories available: screen, tripod, offset on request