CELLS
Montena TEM cells (tri-plate cells) are well suited for immunity testing to electromagnetic fields of small objects according to European (CE) and automotive standards (SAE J1113-24 or ISO11452-3) or for biological experiments. It is very easy to control the functions of the equipment under test. Another very interesting application is the calibration of field probes because the field inside our TEM cells is known with high precision.
REF | Plate height | Frequency range | max field level | Nota |
TEM220 | 36.4 cm | 0 to 220 MHz | 800 V/m | open TEM cells |
TEM500 | 14.7 cm | 0 to 500 MHz | 1.5 kV/m | |
TEM1000 | 7.4 cm | 0 to 1 GHz | 2.6 kV/m | |
TEM3000 | 2.5 cm | 0 to 3 GHz | 5.6 kV/m |
GTEM
Frequency range : DC – 20 GHz depending on models
set up height: 250 mm up to 2500 mm
many options and accessories available: electrical options, gas, water feedthrough plates, honeycomb panel, Fans, Empty technical panel, trolley